The Annals of Thoracic Surgery, Vol 23, 576-577, Copyright © 1977 by The Society of Thoracic Surgeons
GN Olinger and J Maloney JV
A case of bacterial endocarditis from an aortic valve prosthesis is
described in which subannular pseudoaneurysm caused discontinuity of the
aorta and left ventricle. Successful repair was accomplished using compound
sponge-felt to bolster the left ventricular outflow tract and to obliterate
the aneurysm.
ARTICLES
Repair of left ventricular-aortic discontinuity complicating endocarditis from an aortic valve prosthesis
This article has been cited by other articles:
![]() |
D. Liotta, A. Diluch, A. Malusardi, and M. del Rio Congenital mitral-aortic discontinuity Ann. Thorac. Surg., January 1, 2002; 73(1): 274 - 277. [Abstract] [Full Text] [PDF] |
||||