ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Philips, P. A.
Right arrow Articles by Bregman, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Philips, P. A.
Right arrow Articles by Bregman, D.

The Annals of Thoracic Surgery, Vol 23, 45-51, Copyright © 1977 by The Society of Thoracic Surgeons


ARTICLES

Intraoperative application of intraaortic balloon counterpulsation determined by clinical monitoring of the endocardial viability ratio

PA Philips and D Bregman

Persistent unrecognized subendocardial ischemia with development of subendocardial necrosis is a major cause of patient death following cardiopulmonary bypass. The lesion is caused by a discrepancy between the oxygen needs of subendocardial muscle and the available blood supply. If sole reliance is placed upon monitoring conventional vital signs, the more subtle factors contributing to decreased blood flow may go unrecognized. Reported studies have confirmed that the adequacy of subendocardial perfusion can be predicted by calculating the supply/demand ratio, defined as the ratio of the diastolic pressure- time index (DPTI) divided by the systolic pressure-time index (TTI). An analog computer was designed and built that measures the area under the systolic and diastolic component, calculates the DPTI/TTI ratio, and digitally displays the result as the endocardial viability ratio (evr). The EVR was used to determine the adequacy of left ventricular subendocardial blood flow in 64 consecutive patients undergoing cardiac operations. Unidirectional intraaortic balloon counterpulsation (IABC) was utilized in 14 patients with 9 long-term survivors. The difference in mean EVR between survivors and nonsurvivors at the initiation of balloon support was statistically significant. Early application of unidirectional IABC when subendocardial ischemia persists following open cardiac procedures may prevent deterioration to subendocardial necrosis with subsequent morbidity or mortality.


This article has been cited by other articles:


Home page
J Biomater ApplHome page
J. N. Nanas, M. Anastasiou-Nana, and S. D. Moulopoulos
Experimental and Clinical Evaluation of a Counterpulsation Device
J Biomater Appl, April 1, 1990; 4(4): 362 - 373.
[Abstract]


Home page
PerfusionHome page
J. Chalmers and T. Graham
Review article : Mechanical ventricular support in the management of postcardiotomy cardiogenic shock
Perfusion, October 1, 1989; 4(4): 243 - 253.
[Abstract] [PDF]


Home page
VASC ENDOVASCULAR SURGHome page
J. M. Smith, L. D. Joyce, H. G. Mauer, and R. C. Lillehei
Intraaortic Balloon Counterpulsation: A Review
Vascular and Endovascular Surgery, November 1, 1978; 12(6): 377 - 384.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1977 by The Society of Thoracic Surgeons.