Ann Thorac Surg 1976;21:322-327
© 1976 The Society of Thoracic Surgeons
From the Department of Surgery, University of California, Irvine, College of Medicine, Irvine, CA.
Accepted for publication September 16, 1975.
* Address reprint requests to Dr. Gazzaniga, Department of Surgery, University of California, Irvine, College of Medicine, Irvine, CA 92664
A new microporous, expanded polytetrafluoroethylene arterial prosthesis was evaluated in dogs. The material appears to produce an adequate prosthesis for aortopulmonary anastomosis in animals and can conduct a high rate of blood flow. The graft has been used in 3 patients with pulmonary atresia aged 2 days, 2 months, and 6 months. Thus far all patients are well, growing, and have a loud shunt murmur. The desirable features of this type of anastomosis are presented.
This article has been cited by other articles:
![]() |
P. R. Kandakure, A. K. Dharmapuram, N. Ramadoss, V. Babu, I. M. Rao, and K. S. Murthy Sternotomy Approach for Modified Blalock-Taussig Shunt: Is It a Safe Option? Asian Cardiovasc Thorac Ann, August 1, 2010; 18(4): 368 - 372. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Davies, Y. d'Udekem, and C. P. Brizard Cyanoacrylate Adhesive Coating for the Treatment of Serous Leaks From Modified Blalock-Taussig Gore-Tex Shunts Ann. Thorac. Surg., November 1, 2006; 82(5): 1922 - 1923. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. F. Dogan, U. Duman, T. Karagoz, S. Ozkutlu, and U. Ersoy Diagnosis of perigraft seroma formation by use of echocardiography after modified Blalock-Taussig shunt Eur Heart J Cardiovasc Imaging, October 1, 2005; 6(5): 385 - 387. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. R. van Rijn, R. M. F. Berger, M. H. Lequin, and S. G. F. Robben Development of a Perigraft Seroma Around Modified Blalock-Taussig Shunts: Imaging Evaluation Am. J. Roentgenol., March 1, 2002; 178(3): 629 - 633. [Abstract] [Full Text] [PDF] |
||||
![]() |
Q. Chen and J. L. Monro Division of modified Blalock-Taussig shunt at correction avoids distortion of the pulmonary artery Ann. Thorac. Surg., April 1, 2001; 71(4): 1265 - 1266. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. N. Gates, H. Laks, and K. Johnson Side-to-Side Aorto-Gore-Tex Central Shunt Ann. Thorac. Surg., February 1, 1998; 65(2): 515 - 516. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Bogats, E. Kertesz, M. Katona, A. Toszegi, and G. S. Kovacs Modified Blalock-Taussig Shunt Using Allograft Saphenous Vein: Six Years' Experience Ann. Thorac. Surg., January 1, 1996; 61(1): 58 - 62. [Abstract] [Full Text] |
||||
![]() |
J. Odim, M. Portzky, D. Zurakowski, G. Wernovsky, R. P. Burke, J. E. Mayer Jr, A. R. Castaneda, and R. A. Jonas Sternotomy Approach for the Modified Blalock-Taussig Shunt Circulation, November 1, 1995; 92(9): 256 - 261. [Abstract] [Full Text] |
||||
![]() |
V. L. Evans, G. L. Hallman, T. A. Vargo, and H. P. Gutgesell False Aneurysm of the Ascending Aorta from an Expanded Polytetrafluoroethylene (Gore-Tex) Aortopulmonary Shunt Ann. Thorac. Surg., June 1, 1985; 39(6): 573 - 575. [Abstract] [PDF] |
||||
![]() |
C. R. Youmans JR and R. H. Smiley Present Status of Peripheral Vascular Grafts: 36-Month Polytetrafluoroethylene Results Vascular and Endovascular Surgery, September 1, 1981; 15(5): 330 - 346. [PDF] |
||||
![]() |
J. J. Lamberti, C. Campbell, R. L. Replogle, C. Anagnostopoulos, C.-Y. Lin, P. Chiemmongkoltip, and R. Arcilla The Prosthetic (Teflon) Central Aortopulmonary Shunt for Cyanotic Infants Less Than Three Weeks Old: Results and Long-Term Follow-up Ann. Thorac. Surg., December 1, 1979; 28(6): 568 - 577. [Abstract] [PDF] |
||||
![]() |
W. H. Heydorn, R. Zajtchuk, J. Miller, and G. F. Schuchmann Gore-Tex Grafts for Replacement of the Superior Vena Cava Ann. Thorac. Surg., June 1, 1977; 23(6): 539 - 544. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |