Ann Thorac Surg 1975;20:239-248
© 1975 The Society of Thoracic Surgeons
From the Mayo Clinic and Mayo Foundation, Rochester, Minn.
* Address reprint requests to Dr. Pluth, Mayo Clinic and Mayo Foundation, Rochester, Minn. 55901
From February, 1971, through February, 1974, heart valves of 510 patients were replaced with cloth-covered Braunwald-Cutter prostheses. The data indicate that cloth encapsulation of the prosthetic cage is associated with a reduction in thromboembolic complications, particularly for mitral valves. Cloth wear on the distal strut, however, is not prevented by use of a Silastic poppet and appears to be a typical finding in aortic valves recovered or inspected after 3 months. Excessive poppet wear has also been noted in the aortic position; poppet embolization has occurred on 2 occasions, and a third patient was found, at the time of reoperation for periprosthetic leak, to have poppet wear sufficient to permit embolization. Although there have been no reports of clinical malfunction of the mitral prosthesis at the time of this writing, further long-term observation of these patients appears warranted.
This article has been cited by other articles:
![]() |
S. Aoyagi, S. Fukunaga, K. Arinaga, Y. Yokokura, H. Yokokura, and N. Egawa Late Re-operation for Aortic and Mitral Starr-Edwards Ball Valve Prostheses Asian Cardiovasc Thorac Ann, December 1, 2006; 14(6): 467 - 471. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Ismeno, A. Renzulli, M. De Feo, A. Della Corte, F. E. Covino, and M. Cotrufo Standard versus hemodynamic plus 19-mm St Jude Medical aortic valves J. Thorac. Cardiovasc. Surg., April 1, 2001; 121(4): 723 - 728. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. A. Abdulali, N. P. Silverton, F. J. Schoen, N. R. Saunders, and M. I. Ionescu Late Outcome of Patients with Braunwald-Cutter Mitral Valve Replacement Ann. Thorac. Surg., December 1, 1984; 38(6): 579 - 585. [Abstract] [PDF] |
||||
![]() |
W. Daenen, A. Nevelsteen, P. van Cauwelaert, E. de Maesschalk, J. Willems, and G. Stalpaert Nine Years' Experience with the Bjork-Shiley Prosthetic Valve: Early and Late Results of 932 Valve Replacements Ann. Thorac. Surg., June 1, 1983; 35(6): 651 - 663. [Abstract] [PDF] |
||||
![]() |
R. E. Clark, W. M. Swanson, J. L. Kardos, R. W. Hagen, and R. A. Beauchamp Durability of Prosthetic Heart Valves Ann. Thorac. Surg., October 1, 1978; 26(4): 323 - 335. [Abstract] [PDF] |
||||
![]() |
A. O. FAYEMI, M. ALI, E. V. BRAUN, and F. GILROY Poppet Embolization From a Braunwald-Cutter Aortic Valve Prosthesis Arch Surg, April 1, 1977; 112(4): 538 - 538. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |