ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pluth, J. R.
Right arrow Articles by Danielson, G. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pluth, J. R.
Right arrow Articles by Danielson, G. K.

The Annals of Thoracic Surgery, Vol 20, 239-248, Copyright © 1975 by The Society of Thoracic Surgeons


ARTICLES

Aortic and mitral valve replacement with cloth-covered Braunwald-Cutter prosthesis. A three-year follow-up

JR Pluth, JC Broadbent, DA Barnhorst and GK Danielson

From February, 1971, through February, 1974, heart valves of 510 patients were replaced with cloth-covered Braunwald-Cutter prostheses. The data indicate that cloth encapsulation of the prosthetic cage is associated with a reduction in thromboembolic complications, particularly for mitral valves. Cloth wear on the distal strut, however, is not prevented by use of a Silastic poppet and appears to be a typical finding in aortic valves recovered or inspected after 3 months. Excessive poppet wear has also been noted in the aortic position; poppet embolization has occurred on 2 occasions, and a third patient was found, at the time of reoperation for periprosthetic leak, to have opppet wear sufficient to permit embolization. Although there have been no reports of clinical malfunction of the mitral prosthesis at the time of this writing, further long-term observation of these patients appears warranted.


This article has been cited by other articles:


Home page
Asian Cardiovasc. Thorac. Ann.Home page
S. Aoyagi, S. Fukunaga, K. Arinaga, Y. Yokokura, H. Yokokura, and N. Egawa
Late Re-operation for Aortic and Mitral Starr-Edwards Ball Valve Prostheses
Asian Cardiovasc Thorac Ann, December 1, 2006; 14(6): 467 - 471.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
G. Ismeno, A. Renzulli, M. De Feo, A. Della Corte, F. E. Covino, and M. Cotrufo
Standard versus hemodynamic plus 19-mm St Jude Medical aortic valves
J. Thorac. Cardiovasc. Surg., April 1, 2001; 121(4): 723 - 728.
[Abstract] [Full Text] [PDF]


Home page
Arch SurgHome page
A. O. FAYEMI, M. ALI, E. V. BRAUN, and F. GILROY
Poppet Embolization From a Braunwald-Cutter Aortic Valve Prosthesis
Arch Surg, April 1, 1977; 112(4): 538 - 538.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1975 by The Society of Thoracic Surgeons.